EXAM CDCP ANSWERS & CDCP SAMPLE QUESTIONS

Exam CDCP Answers & CDCP Sample Questions

Exam CDCP Answers & CDCP Sample Questions

Blog Article

Tags: Exam CDCP Answers, CDCP Sample Questions, CDCP Exam Dumps Collection, CDCP Reliable Braindumps Ebook, Latest CDCP Version

Exam4Docs Certified Data Centre Professional (CDCP) (CDCP) exam dumps save your study and preparation time. Our experts have added hundreds of Certified Data Centre Professional (CDCP) (CDCP) questions similar to the real exam. You can prepare for the Certified Data Centre Professional (CDCP) (CDCP) exam dumps during your job. You don't need to visit the market or any store because Exam4Docs Certified Data Centre Professional (CDCP) (CDCP) exam questions are easily accessible from the website.

EXIN CDCP Exam Syllabus Topics:

TopicDetails
Topic 1
  • Light: This topic covers light fixture types and placement, emergency lighting, and emergency Power Supply (EPS).
Topic 2
  • Power Infrastructure: It focuses ATS and STS systems, redundancy levels and techniques, static and dynamic UPS systems, battery types, thermo-graphics, and renewable energy factor (REF).
Topic 3
  • Cooling Infrastructure: The topic focuses on liquid immersion cooling, supplemental cooling options, sensible and latent heat definitions, and temperature and humidity recommendations.
Topic 4
  • Designing a Scalable Network Infrastructure: It covers ANSI
  • TIA-942 cabling hierarchy, network redundancy, structured Cabling System, and planning considerations.
Topic 5
  • Equipment Racks: It discusses power rail
  • strip options, security considerations, and rack standards, properties and selection criteria.
Topic 6
  • Water Supply: This topic is all about water supply techniques and application areas.
Topic 7
  • Fire Safety
  • Protection: This topic gives an understanding of standards for fire suppression, detection systems, total flooding fire suppression techniques, and handheld extinguishers. Additionally, it covers Signage and safety.
Topic 8
  • Electro Magnetic Fields: The topic deals with effects of EMF on human health and equipment (H)EMP, standards, and EMF shielding solutions.
Topic 9
  • Data Centre Location, Building and Construction: It focuses on appropriate sites and components of an effective data centre and supporting facilities setup.
Topic 10
  • Raised Floor
  • Suspended Ceiling: The topic discusses applicable standards, signal reference grid, and disability act and regulations.

>> Exam CDCP Answers <<

CDCP Sample Questions, CDCP Exam Dumps Collection

With our EXIN CDCP study matetials, you can make full use of those time originally spent in waiting for the delivery of exam files so that you can get preparations as early as possible. There is why our EXIN CDCP learning prep exam is well received by the general public.

EXIN Certified Data Centre Professional (CDCP) Sample Questions (Q37-Q42):

NEW QUESTION # 37
The termination of the ability of a product to perform its required function can be defined as.

  • A. Failure
  • B. Hindrance
  • C. Termination
  • D. Obstacle

Answer: A

Explanation:
According to the EPI Data Centre Professional (CDCP®) Preparation Guide, failure is defined as "the termination of the ability of a product to perform its required function" (page 9). Failure can occur due to various reasons, such as wear and tear, design flaws, human errors, environmental factors, or external events.
Failure can affect the availability, reliability, and performance of a product, system, or service.
References:
*EPI Data Centre Professional (CDCP®) Preparation Guide, page 9
*What is Failure? | Definition from WhatIs.com


NEW QUESTION # 38
What is the most preferred unit of measure for cooling capacity?

  • A. BTU
  • B. Horsepower
  • C. Watt
  • D. Ton

Answer: C

Explanation:
Cooling capacity is the measure of a cooling system's ability to remove heat from a space. The most preferred unit of measure for cooling capacity is watt (W), which is the SI unit for power. Watt is defined as the amount of energy transferred or converted per unit time. One watt is equal to one joule of energy per second. Using watt as the unit of measure for cooling capacity allows for easy comparison and calculation of the cooling performance and efficiency of different cooling systems.
Other units of measure for cooling capacity are ton, BTU, and horsepower, but they are less common and less convenient than watt. Ton is a unit of measure that describes how much water at freezing temperature can be frozen in 24 hours, equivalent to 3.5 kW or 12,000 BTU/h. BTU (British Thermal Unit) is a unit of measure that describes the amount of heat required to raise the temperature of one pound of water by one degree Fahrenheit, equivalent to 0.293 W. Horsepower is a unit of measure that describes the rate at which work is done, equivalent to 746 W.
References:
*Data Centre Professional (CDCP®) Reference Materials, page 8, section 2.1.1
*Data Centre Professional (CDCP®) Preparation Guide, page 11, section 2.1.1
*Cooling capacity - Wikipedia
*Air Conditioner BTU Calculator
*Air conditioning 101: Basics, working principle and sizing ... - GlobalSpec
*How is cooling capacity measured? - Sage-Advices
*Everything You Need to Know About Cooling Capacity


NEW QUESTION # 39
Which formula can be used to define risk?

  • A. Risk = Probability * Cost
  • B. Risk = Time * Quality
  • C. Risk = Security * Criminality
  • D. Risk = Impact * Probability

Answer: D

Explanation:
According to the CDCP Preparation Guide1, risk can be defined as the product of impact and probability.
Impact is the measure of the negative consequences or losses that may result from a risk event, such as downtime, data loss, or damage to the data centre. Probability is the measure of the likelihood or frequency of a risk event occurring, based on historical data, expert judgment, or statistical analysis. By multiplying impact and probability, risk can be quantified and compared, which helps in prioritizing and mitigating the risks. For example, a risk event that has a high impact but a low probability may have the same risk level as a risk event that has a low impact but a high probability.
References:
1: CDCP Preparation Guide, page 25, section 2.5.1 2: Data center risk assessment: A decision-making tool3, page 1, section 1 4: Accounting for Risk in Your Data Center Design/Build Strategy5, page 1, section 1 6: A Novel Framework for Data Center Risk Assessment7, page 1, section 1


NEW QUESTION # 40
What should be a consideration when having casters (rollers/wheels) or feet under the rack?

  • A. Casters and feet should not be locked to ensure the racks are still able to be moved to another position.
  • B. The casters and feet should be larger to avoid a too heavy point load on the floor tile.
  • C. Casters and feet should be of a soft material, for example rubber, to avoid damage to the raised floor tile.
  • D. Skirts at the bottom of the rack to avoid air flow between the hot and cold aisles.

Answer: B

Explanation:
The casters and feet under the rack are used to support the weight of the rack and its equipment, and to allow the rack to be moved if needed. However, the casters and feet should also be designed to avoid putting too much pressure on the floor tile, especially if the data centre uses a raised floor system. A too heavy point load on the floor tile can cause the tile to crack, deform, or collapse, which can damage the rack, the equipment, and the underlying infrastructure. To prevent this, the casters and feet should be larger, so that they can distribute the weight over a larger area and reduce the point load. The casters and feet should also be compatible with the floor type and the load rating of the floor tile.
References:
1: CDCP Preparation Guide, page 22, section 2.4.1.1 2: Raised Floor Design Considerations for Data Center3, page 1, section 1 4: [SOLVED] server rack on casters or feet5, page 1, section 1


NEW QUESTION # 41
Which one of the following is an example of Indirect Cost?

  • A. Legal fees
  • B. System recovery
  • C. Cost revenues
  • D. Damaged brand perception

Answer: D

Explanation:
Damaged brand perception is an example of an indirect cost because it is not directly related to a specific product or service, but rather to the overall reputation and image of the company. Damaged brand perception can result from various factors, such as poor quality, customer dissatisfaction, security breaches, or negative publicity. Damaged brandperception can affect the company's ability to attract and retain customers, partners, and investors, and thus reduce its profitability and competitiveness.
References: EPI Data Centre Training Framework, Indirect Cost: Definition and Example, What Is Indirect Cost? Definition, Types and Examples.
Learn more
1 indeed.com2 o


NEW QUESTION # 42
......

The privacy protection of users is an eternal issue in the internet age. Many illegal websites will sell users' privacy to third parties, resulting in many buyers are reluctant to believe strange websites. But you don't need to worry about it at all when buying our CDCP study materials. We assure you that we will never sell users’ information because it is damaging our own reputation. In addition, when you buy our CDCP Study Materials, our website will use professional technology to encrypt the privacy of every user to prevent hackers from stealing.

CDCP Sample Questions: https://www.exam4docs.com/CDCP-study-questions.html